import time
import statistics
import sqlite3
from olsndot import Olsndot, Driver
from datetime import datetime
from pyBusPirateLite import Buspirate
AVERAGE_READINGS = 16
if __name__ == '__main__':
import argparse
parser = argparse.ArgumentParser()
parser.add_argument('channels', type=str, help='olsndot channels to test, format: 0-3,5,7,8-10')
parser.add_argument('run_name')
parser.add_argument('olsndot_port', nargs='?', default='/dev/serial/by-id/usb-FTDI_FT232R_USB_UART_A50285BI-if00-port0')
parser.add_argument('buspirate_port', nargs='?', default='/dev/serial/by-id/usb-FTDI_FT232R_USB_UART_AD01W1RF-if00-port0') # FIXME
parser.add_argument('-d', '--database', nargs='?', default='results.sqlite3', help='sqlite3 database file to store results in')
parser.add_argument('-m', '--mac', type=int, nargs='?', default=0xDEBE10BB, help='olsndot MAC address')
args = parser.parse_args()
def parse_channels(channels):
for spec in channels.split(','):
if str.isnumeric(spec):
yield int(spec)
else:
low, high = spec.split('-')
yield from range(int(low), int(high)+1)
channels = list(parse_channels(args.channels))
db = sqlite3.connect(args.database)
db.execute("""
CREATE TABLE IF NOT EXISTS runs (
run_id INTEGER PRIMARY KEY,
name TEXT,
comment TEXT,
uut_mac TEXT, -- hex-string formatted 32-bit mac of the uut
timestamp REAL -- unix timestamp in fractional seconds
)""")
db.execute("""
CREATE TABLE IF NOT EXISTS measurements (
measurement_id INTEGER PRIMARY KEY,
run_id INTEGER,
channel INTEGER,
duty_cycle REAL, -- setpoint duty cycle as a float between 0.0 and 1.0
voltage REAL, -- volts
voltage_stdev REAL, -- volts
timestamp REAL, -- unix timestamp in fractional seconds
FOREIGN KEY (run_id) REFERENCES runs)""")
bp = Buspirate(args.buspirate_port)
bp.power_on = True
uut = Olsndot(args.mac)
d = Driver(args.olsndot_port, devices=[uut])
print('Connected to uut:', uut)
with db:
cur = db.cursor()
cur.execute('INSERT INTO runs(name, uut_mac, timestamp) VALUES (?, ?, ?)',
(args.run_name, args.mac, time.time()))
run_id = cur.lastrowid
print('Starting run {} at {:%y-%m-%d %H:%M:%S:%f}'.format(run_id, datetime.now()))
print('mac={:08x} channels={}'.format(args.mac, ','.join('{:02d}'.format(ch) for ch in channels)))
print('[measurement id] " " [hex setpoint value] "(" [float duty cycle] ")" " " [reading (V)]')
for ch in channels:
for i in range(-1, uut.nbits):
fb = [0]*uut.nchannels
if i == -1:
val = 0
else:
val = 1<<i
duty_cycle = val/(2**uut.nbits)
extra_shift = 16-uut.nbits
val <<= extra_shift
fb[ch] = val
uut.send_framebuf(fb)
time.sleep(0.2)
readings = [ bp.adc_value for _ in range(AVERAGE_READINGS) ]
mean, stdev = statistics.mean(readings), statistics.stdev(readings)
with db:
cur = db.cursor()
cur.execute('''
INSERT INTO measurements (
run_id, channel, duty_cycle, voltage, voltage_stdev, timestamp
) VALUES (?, ?, ?, ?, ?, ?)''',
(run_id, ch, duty_cycle, mean, stdev, time.time()))
print('{:08d} ch={} {:04x}({:6.5f}): {:5.4f} stdev {:5.4}'.format(
cur.lastrowid, ch, val, duty_cycle, mean, stdev))
uut.send_framebuf([0]*uut.nchannels)
bp.power_on = False
|