From 0f70b225cc394338e9c37c1b1c34c3e73609f7d6 Mon Sep 17 00:00:00 2001 From: jaseg Date: Tue, 21 Jun 2022 10:53:13 +0200 Subject: tests: add missing allegro test files --- gerbonara/tests/resources/allegro/Read_Me.1 | 85 +++++++++++++++++++++++++++++ 1 file changed, 85 insertions(+) create mode 100644 gerbonara/tests/resources/allegro/Read_Me.1 (limited to 'gerbonara/tests/resources/allegro/Read_Me.1') diff --git a/gerbonara/tests/resources/allegro/Read_Me.1 b/gerbonara/tests/resources/allegro/Read_Me.1 new file mode 100644 index 0000000..5b1a12a --- /dev/null +++ b/gerbonara/tests/resources/allegro/Read_Me.1 @@ -0,0 +1,85 @@ +----------------------------- +ANALOG DEVICES - Division +----------------------------- + +Product Line: + +Board Name: 08_057494d + +P/N: 09-057494 Rev d + +PEOPLE INVOLVED +--------------------------------------- +Design Engineer involved: +Layout Designer involved: 1 + +CAD TOOLS +---------------------------------------- +Layout Software and Version: Allegro 17.2 +Schematic Software and Version: 17.2 + + +Notes: + +FLASH PAD GEOMETRY: + + NEGATIVE LAYER FLASH PADS; + + 1. Thermal Relief flash Pads. Are dimensioned in mils, + without leading zeros. They are encoded as follows: + + t 90 70 15x45 sp4 + | | | | |_ number of spokes + | | | | + | | | |_spoke width and angle + | | | + | | |_inside diameter + | | + | |_outside diameter + | + |_thermal relief + + 2. tdirect is used to make full contact with the plane. + A 5 mil circle or blank flash may be substituted. + + 3. Anti-pad with copper pad retained. Used on negative layers + where pad must be used as land contact for blind or buried vias + + s ap 20 12 + | | | |_ inside pad dimention + | | | + | | |_ outside anti-pad dimention + | | + | |_ anti-pad designator + | + |_ s = square i.d. o.d. dimentions + c = circular i.d. o.d. dimentions + + POSITIVE LAYER FLASH PADS; + + 1. cir40 (cir#) is used to indicate a spotting pad for non-plated holes. + A 40 (or #) mil circle or blank flash may be substituted. + + 2. Doughnut pads are used where land is required around non-plated holes + with relief of the land for the non-plated drill. They are encoded as follows: + + dp 250 x 190 + | | |_ inside diameter + | | + | |_ outside diameter + | + |_ doughnut pad + +________________________________________________________________________ + +The following listed contacts are for the initial design order indicated +by the lot and dock delivery date listed below. Subsequent questions are +to be routed through the agent indicated on the purchase order. + +Analog Devices Inc. - + +Primary Contact : 1 +Phone : +Fax : +Boards to be bare board tested : YES +Boards to be TDR tested : YES -- cgit