-Header
- CHECK KEYWORDS "Warn"
- Mesh DB "." "mesh"
-End
-
-Simulation
- Mesh Levels = 1
- Max Output Level = 7
- Coordinate System = Cartesian
- Coordinate Mapping(3) = 1 2 3
- Simulation Type = Steady state
- Steady State Max Iterations = 1
- Output Intervals = 1
- Timestepping Method = BDF
- Simulation Timing = True
- BDF Order = 1
- Solver Input File = case.sif
- Post File = case.vtu
- Output File = case.result
-End
-
-Constants
- Stefan Boltzmann = 5.6704e-08
- Permittivity of Vacuum = 8.8541878128e-12
- Gravity(4) = 0 -1 0 9.80665
- Boltzmann Constant = 1.380649e-23
- Unit Charge = 1.602176634e-19
-End
-
-! airEqn
-Equation 1
- Active Solvers(1) = 1 ! Static_Current_Conduction, Magneto_Dynamics, Magneto_Dynamics_Calculations,
-End
-
-! Static_Current_Conduction
-Solver 1
- Equation = Electrostatics
- Procedure = "StatElecSolve" "StatElecSolver"
- Variable = Potential
- Calculate Electric Field = True
- Calculate Electric Energy = True
- Exec Solver = Always
- Stabilize = True
- Bubbles = False
- Lumped Mass Matrix = False
- Optimize Bandwidth = True
- Steady State Convergence Tolerance = 1e-05
- Nonlinear System Convergence Tolerance = 1e-07
- Nonlinear System Max Iterations = 20
- Nonlinear System Newton After Iterations = 3
- Nonlinear System Newton After Tolerance = 0.001
- Nonlinear System Relaxation Factor = 1
- Linear System Solver = Iterative
- Linear System Iterative Method = BiCGStab
- Linear System Max Iterations = 500
- Linear System Convergence Tolerance = 1e-10
- BiCGstabl polynomial degree = 2
- Linear System Preconditioning = ILU0
- Linear System ILUT Tolerance = 0.001
- Linear System Abort Not Converged = False
- Linear System Residual Output = 10
- Linear System Precondition Recompute = 1
-End
-
-
-! air
-Material 1
- Density = 1.1885
- Electric Conductivity = 0.0
- Heat Capacity = 1006.4
- Heat Conductivity = 0.025873
- Relative Permeability = 1
- Relative Permittivity = 1
-End
-
-! ro4003c
-Material 2
- Density = 1790
- Electric Conductivity = 0.0
- Relative Permeability = 1
- Relative Permittivity = 3.55
-End
-
-! copper
-Material 3
- Density = 8960.0
- Electric Conductivity = 59600000
- Emissivity = 0.012
- Heat Capacity = 415.0
- Heat Conductivity = 401.0
- Relative Permeability = 1
-End
-
-! trace
-Body 1
- Target Bodies(1) = 3
- Material = 3 ! copper
- Body Force = 1 ! electric_potential
-End
-
-! substrate
-Body 2
- Target Bodies(1) = 1
- Equation = 1 ! airEqn
- Material = 2 ! ro4003c
-End
-
-! airbox
-Body 3
- Target Bodies(1) = 2
- Equation = 1 ! airEqn
- Material = 1 ! air
-End
-
-! interface_top
-Body 4
- Target Bodies(1) = 4
- Material = 3 ! copper
-End
-
-! interface_bottom
-Body 5
- Target Bodies(1) = 5
- Material = 3 ! copper
-End
-
-
-! FarField
-Boundary Condition 1
- Target Boundaries(1) = 6
- Electric Infinity BC = True
-End
-
-! Vplus
-Boundary Condition 2
- Target Boundaries(1) = 4
- Potential = 1.0
- Save Scalars = True
-End
-
-! Vminus
-Boundary Condition 3
- Target Boundaries(1) = 5
- Potential = 0.0
-End
-
-
-! electric_potential
-Body Force 1
- Electric Potential = Equals "Potential"
-End
-
-
-